TORONTO, Sept. 19,
2022 /CNW/ - QC Copper and Gold Inc. ("QC
Copper" or the "Company") (TSXV: QCCU) (OTCQB: QCCUF) is
pleased to report 23 holes that continue to demonstrate wide zones
of high-grade copper and gold within Opemiska's conceptual open
pit. These new assay results are in the Starter Pit and Saddle
Zone area on the Opemiska Copper-Gold Property.
Highlights from the Starter Pit Area Include:
OPM-22-201
|
0.44% Cu and 0.11
gpt Au over 58.5m (from 261m to 319.5m)
|
OPM-22-203
|
0.48% Cu and 0.17
gpt Au over 78m (from 127.5m to 205.5m)
|
OPM-22-217
|
0.63% Cu and 0.13
gpt Au over 12m (from 120m to 132m)
|
And
|
0.62% Cu and 0.23
gpt Au over 54.0m (from 234m to 238m)
|
OPM-22-218
|
0.82% Cu and 0.19
gpt Au over 18m (from 61.5m to 79.5m)
|
OPM-22-220
|
1.52% Cu and 0.16
gpt Au over 19m (from 80m to 99m)
|
And
|
0.97% Cu and 0.26
gpt Au over 35m (from 121m to 156m)
|
OPM-22-223*
|
0.59% Cu and 0.18
gpt Au over 33m (from 27m to 60m)
|
OPM-22-226*
|
1.03% Cu and 0.50
gpt Au over 40m (from 1.0m to 41m)
|
OPM-22-227*
|
0.45% Cu and 0.35
gpt Au over 22.5m (from 45m to 67.5m)
|
Highlights from the Saddle Zone Results:
And
|
0.78% Cu and 0.14
gpt Au over 22.5m (from 234m to 256.5m)
|
Click here to view cross sections and plan view of reported
intersections.
Summary of reported composite intersections: Table
1
Hole
ID
|
UTM
Coordinates (East/North)
|
From
(m)
|
To
(m)
|
Interval
(m)
|
Grade
|
Copper
(%)
|
Gold
(gpt)
|
Silver
(gpt)
|
Zinc
(ppm)
|
Cobalt
(ppm)
|
OPM-22-199
|
509919 /
5515250
|
160.5
|
169.5
|
9
|
0.248
|
0.155
|
2.08
|
429
|
52
|
OPM-22-200
|
510276 /
5515272
|
133.5
|
150
|
16.5
|
0.464
|
0.104
|
1.8
|
76
|
54
|
OPM-22-201
|
509930 /
5515356
|
261
|
319.5
|
58.5
|
0.44
|
0.114
|
2.19
|
76
|
26
|
OPM-22-202
|
510321 /
5515285
|
87
|
91.5
|
4.5
|
0.249
|
0.011
|
1.47
|
37
|
25
|
OPM-22-203
|
509835 /
5515276
|
127.5
|
205.5
|
78
|
0.488
|
0.179
|
2.66
|
91
|
36
|
303
|
328.5
|
25.5
|
0.254
|
0.074
|
1.18
|
61
|
39
|
OPM-22-204
|
509850 /
5515132
|
42
|
52.5
|
10.5
|
0.196
|
0.069
|
1.27
|
60
|
36
|
93
|
108
|
15
|
0.364
|
0.161
|
1.93
|
132
|
31
|
186
|
211.5
|
25.5
|
0.206
|
0.094
|
0.84
|
85
|
31
|
330
|
350
|
20
|
0.307
|
0.041
|
1.89
|
93
|
46
|
OPM-22-206
|
510294 /
5515327
|
121.5
|
132
|
10.5
|
0.491
|
0.111
|
2.39
|
115
|
62
|
397.5
|
405
|
7.5
|
0.798
|
0.259
|
2.68
|
95
|
68
|
OPM-22-207
|
509708 /
5515069
|
3.5
|
18
|
14.5
|
0.4
|
0.265
|
2.07
|
50
|
44
|
OPM-22-210
|
510276 /
5515345
|
416.3
|
438
|
21.7
|
0.279
|
0.103
|
2.62
|
157
|
45
|
OPM-22-212
|
510345 /
5515344
|
147
|
202.5
|
55.5
|
0.459
|
0.07
|
2.62
|
89
|
55
|
234
|
256.5
|
22.5
|
0.779
|
0.144
|
5.71
|
256
|
97
|
OPM-22-213
|
510353 /
5515387
|
156
|
166.5
|
10.5
|
0.405
|
0.029
|
2.26
|
495
|
62
|
OPM-22-215
|
509825 /
5515039
|
276
|
279.3
|
3.3
|
0.373
|
0.106
|
2.14
|
70
|
47
|
OPM-22-216
|
510337 /
5515403
|
273
|
277.5
|
4.5
|
0.57
|
0.138
|
3.8
|
134
|
57
|
OPM-22-217
|
509875 /
5515075
|
120
|
132
|
12
|
0.627
|
0.126
|
3.07
|
96
|
39
|
165
|
180
|
15
|
0.628
|
0.165
|
2.92
|
166
|
48
|
424.5
|
429
|
4.5
|
0.383
|
0.057
|
4.2
|
70
|
92
|
OPM-22-218
|
509800 /
5514965
|
2.2
|
21
|
18.8
|
0.204
|
0.169
|
2.67
|
174
|
22
|
61.5
|
79.5
|
18
|
0.815
|
0.194
|
6.36
|
515
|
33
|
114
|
118.5
|
4.5
|
0.848
|
0.259
|
9.53
|
158
|
56
|
168
|
186
|
18
|
0.385
|
0.096
|
2.06
|
63
|
36
|
OPM-22-219
|
510298 /
5515403
|
36
|
42
|
6
|
0.324
|
0.028
|
2.5
|
112
|
68
|
294
|
318
|
24
|
0.301
|
0.073
|
1.52
|
49
|
23
|
334.5
|
339
|
4.5
|
0.318
|
0.207
|
1.9
|
68
|
75
|
OPM-22-220
|
509770 /
5514922
|
56
|
68
|
12
|
0.361
|
0.126
|
2.76
|
63
|
39
|
80
|
99
|
19
|
1.523
|
0.161
|
8.04
|
466
|
54
|
121
|
156
|
35
|
0.97
|
0.264
|
4.39
|
145
|
75
|
265.5
|
269
|
3.5
|
0.722
|
0.283
|
3.11
|
74
|
45
|
OPM-22-222
|
509735 /
5514870
|
51
|
90
|
53
|
0.221
|
0.123
|
1.33
|
60
|
42
|
156
|
175.5
|
19.5
|
0.349
|
0.459
|
1.14
|
47
|
21
|
OPM-22-223*
|
509704 /
5514853
|
27
|
60
|
33
|
0.585
|
0.18
|
3.99
|
122
|
52
|
286.5
|
316.5
|
30
|
0.218
|
0.102
|
1.24
|
64
|
52
|
OPM-22-224
|
510203 /
5515466
|
61.5
|
69
|
7.5
|
0.285
|
0.073
|
2.86
|
105
|
137
|
OPM-22-225*
|
510288 /
5515450
|
117
|
124.5
|
7.5
|
0.308
|
0.065
|
1.48
|
61
|
34
|
OPM-22-226*
|
509670 /
5514821
|
1
|
41
|
40
|
1.029
|
0.498
|
4.46
|
93
|
48
|
OPM-22-227*
|
509670 /
5514821
|
45
|
67.5
|
22.5
|
0.446
|
0.351
|
1.91
|
80
|
50
|
102
|
109.5
|
7.5
|
0.286
|
0.138
|
2.2
|
55
|
43
|
159.4
|
168.7
|
9.3
|
0.203
|
0.067
|
0.67
|
66
|
35
|
*:
|
Only Partial Results
Available.
|
Details on the Starter
Pit Results
Results presented for the Springer Mine area cover the Starter
Pit area and include results from the Mill Zone, the Gap Area, and
the area south of the Vein #3 as shown on the map and selected
sections. Some of these intersections are exceptional, such as hole
220, which cut 2 zones over 76 m core
length starting at 80m that assayed
1.5% copper and 0.16 gpt gold over 19m followed by 0.97% copper and 0.26 gpt gold
over 35m. Hole 223 cut 33m of 0.59% copper and 0.18 gpt gold starting at
27m and hole 226 cut 40m of 1.03% copper and 0.5 gpt gold. Finally,
nearby hole 227 intersected 22.5m of
0.45% copper and 0.35 gpt gold; these last three highlight the
expected high gold grades near the Gwillim Fault, which forms the
southern limit of the Opemiska Deposit.
Details on the Saddle Zone
Results
Another exceptional intersection was encountered on the Saddle
Zone, where a 110m of variably
mineralized gabbro returned 0.46% copper and 0.07 gpt gold over
55.5m starting at 147m, followed by 0.78% copper and 0.14 gpt gold
over 22.5m.
QP Statement
The technical information contained in this news release has
been reviewed and approved by Charles
Beaudry, P.Geo and géo., Director and Vice President
Exploration for QC Copper & Gold, a Qualified Person, as
defined in "National Instrument 43-101, Standards of Disclosure for
Mineral Projects." For the exploration undertaken by QC
Copper & Gold, all assay batches are accompanied by rigorous
Quality Assurance procedures, including the insertion of standards
and blanks and verification assays in a secondary laboratory. All
the core received from the drill is split in half, bagged and sent
to ALS-Global facilities in Quevillon, Quebec for sample preparation and then the
pulps are shipped to AlS-Global's Vancouver laboratory or some other location in
the world for analysis using ALS-Global's standardized
ISO-compliant methods, all of which are listed in the laboratory
certificates provided with the assay results. The remaining half
core along with the rejects and the pulps returned from the
laboratory are securely stored at QC Copper's facilities in
Chapais, Quebec. Quality Control
results, including the laboratory's control samples, are evaluated
immediately on reception of batch results and corrections are
implemented immediately if necessary. All drill collars are
surveyed and positioned in UTM coordinates. Collars are oriented
using a gyroscopic north-finding system and downhole deviations
surveys are done with a single-shot gyroscopic instrument at 30 to
50m intervals. For veins oriented
approximately east-west and dipping towards the north, and drill
holes oriented due south and plunging between 50 and 65 dips, the
true width of mineralized intersections are equal or greater than
80% of the quoted core length composite intervals. This observation
also holds for veins oriented northwest-southeast and dipping
towards the northeast with holes drilled towards the southwest at
225 degrees with dips between 50 and 65 degrees. However, for other
drill hole orientations relative to these veins or other less
common vein orientations, the true widths of mineralized
intersections are less.
For information and updates on QC Copper and Gold, please
visit: www.qccopper.com
And please follow us on Twitter @qccoppergold
Neither TSX Venture Exchange nor its Regulation Services
Provider (as that term is defined in the policies of the TSX
Venture Exchange) accepts responsibility for the adequacy or
accuracy of this release. Certain information in this press release
may contain forward-looking statements. This information is based
on current expectations that are subject to significant risks and
uncertainties that are difficult to predict. Actual results might
differ materially from results suggested in any forward-looking
statements. QC Copper and Gold Inc. assumes no obligation to update
the forward-looking statements, or to update the reasons why actual
results could differ from those reflected in the forward
looking-statements unless and until required by securities laws
applicable to QC Copper and Gold Inc. Additional information
identifying risks and uncertainties is contained in filings by QC
Copper and Gold Inc. with Canadian securities regulators, which
filings are available under QC Copper and Gold Inc. profile
at www.sedar.com.
SOURCE QC Copper & Gold Inc.